Technical Document
Specifications
Brand
Aim-TTiProduct Type
Multimeter
Multimeter Type
Bench
Resistance Resolution
1mΩ
Model Number
1908P
Display Type
Digital
Functions Measured
Temperature, DC Voltage, AC Voltage, Capacitance, DC Current, Frequency, Resistance, AC Current
Maximum AC Current Measurement
10A
Maximum Resistance Measurement
1kΩ
Maximum DC Voltage Measurement
1000V
Maximum DC Current Measurement
10A
True RMS
Yes
DC Current Accuracy
0.05 %
AC Voltage Accuracy
0.3 %
AC Current Accuracy
0.35 %
DC Voltage Accuracy
0.02 %
DC Current Resolution
100nA dc
AC Current Resolution
100nA
DC Voltage Resolution
1 μV
Maximum Frequency
100kHz
Minimum Operating Temperature
5°C
Resistance Measurement Accuracy
±0.05 %
Maximum Operating Temperature
40°C
Width
235 mm
Height
88mm
Length
260mm
Weight
2kg
Standards/Approvals
No
Safety Category Level
CAT II
Battery Type
Rechargeable Ni-MH
Safety Category Voltage
600V
Country of Origin
United Kingdom
Product details
Aim-TTI 1908P Series Dual Measurement Bench Multimeter
Aim-TTi 1908 Series is a dual measurement, dual display bench-top/portable multimeter. It features continuity and diode test, automatic or manual ranging, linear scaling with offset, dB measurements, limits comparison, percentage deviation (%), min-max storage, power measurement in watts or VA, automatic data logging and external triggering. The logger function can store up to 500 readings from the main display in non-volatile memory. The two displays can be used to display a measurement along with the selected range (e.g. 100 Vdc), a measurement in two different units (e.g. AC volts and dBm), the result of a calculated function (e.g. value and % deviation), two parameters of one signal (e.g. AC and DC volts) or two different signals (e.g. AC volts and DC current). Software 1908-PC Link provides remote control of main functions and logging function with graphical and tabular displays (logged data can be exported to a CSV file). Model 1908P can be remotely controlled via its RS232, USB or LAN interface. Model 1908 (non P) can only be controlled via USB.
For an optional GPIB module see stock number 144-5481.
Features and Benefits
Affordable 5.5 digit high performance bench/portable multimeter, 120 000 counts
Dual display (main display and secondary display) and dual measurement capability
Mains power or Internal rechargeable batteries for true portability
High accuracy and resolution 0.02%, 1 μV, 0.1 μA, 1 mΩ
Manual or Auto-ranging
True RMS AC and AC+DC measurement
DC and AC volts, DC and AC current, resistance, capacitance, frequency, and temperature measurement
Measurement post-processing
Continuity and diode checks
Two or four wire selectable ohms measurement
Display nulling and ohms null
Selectable measurement speed
Touch hold mode - holds onto a stable reading until updated
500 point data logger with timer
Temperature measurement for PT100 or PT1000 sensors
Wide range of computing functions e.g. Ax + B
External input/output remote triggering
Closed case calibration
USB interface standard (1908 & 1908P) plus RS232, LAN/LXI
Kensington security slot incorporated
Dimensions 250 x 97 x 295 mm
Weight 3.2 kg
Supplied with
IVI driver, LV/CVI driver, USB driver
Standards
EN61010-1, EN61010-2-030 & EN61010-2-033, EN61326-1 EMC
Stock information temporarily unavailable.
€ 788.81
€ 788.81 Each (Exc. Vat)
€ 954.46
€ 954.46 Each (inc. VAT)
Calibration type
No Calibration
1

€ 788.81
€ 788.81 Each (Exc. Vat)
€ 954.46
€ 954.46 Each (inc. VAT)
Stock information temporarily unavailable.
Calibration type
No Calibration
1

Technical Document
Specifications
Brand
Aim-TTiProduct Type
Multimeter
Multimeter Type
Bench
Resistance Resolution
1mΩ
Model Number
1908P
Display Type
Digital
Functions Measured
Temperature, DC Voltage, AC Voltage, Capacitance, DC Current, Frequency, Resistance, AC Current
Maximum AC Current Measurement
10A
Maximum Resistance Measurement
1kΩ
Maximum DC Voltage Measurement
1000V
Maximum DC Current Measurement
10A
True RMS
Yes
DC Current Accuracy
0.05 %
AC Voltage Accuracy
0.3 %
AC Current Accuracy
0.35 %
DC Voltage Accuracy
0.02 %
DC Current Resolution
100nA dc
AC Current Resolution
100nA
DC Voltage Resolution
1 μV
Maximum Frequency
100kHz
Minimum Operating Temperature
5°C
Resistance Measurement Accuracy
±0.05 %
Maximum Operating Temperature
40°C
Width
235 mm
Height
88mm
Length
260mm
Weight
2kg
Standards/Approvals
No
Safety Category Level
CAT II
Battery Type
Rechargeable Ni-MH
Safety Category Voltage
600V
Country of Origin
United Kingdom
Product details
Aim-TTI 1908P Series Dual Measurement Bench Multimeter
Aim-TTi 1908 Series is a dual measurement, dual display bench-top/portable multimeter. It features continuity and diode test, automatic or manual ranging, linear scaling with offset, dB measurements, limits comparison, percentage deviation (%), min-max storage, power measurement in watts or VA, automatic data logging and external triggering. The logger function can store up to 500 readings from the main display in non-volatile memory. The two displays can be used to display a measurement along with the selected range (e.g. 100 Vdc), a measurement in two different units (e.g. AC volts and dBm), the result of a calculated function (e.g. value and % deviation), two parameters of one signal (e.g. AC and DC volts) or two different signals (e.g. AC volts and DC current). Software 1908-PC Link provides remote control of main functions and logging function with graphical and tabular displays (logged data can be exported to a CSV file). Model 1908P can be remotely controlled via its RS232, USB or LAN interface. Model 1908 (non P) can only be controlled via USB.
For an optional GPIB module see stock number 144-5481.
Features and Benefits
Affordable 5.5 digit high performance bench/portable multimeter, 120 000 counts
Dual display (main display and secondary display) and dual measurement capability
Mains power or Internal rechargeable batteries for true portability
High accuracy and resolution 0.02%, 1 μV, 0.1 μA, 1 mΩ
Manual or Auto-ranging
True RMS AC and AC+DC measurement
DC and AC volts, DC and AC current, resistance, capacitance, frequency, and temperature measurement
Measurement post-processing
Continuity and diode checks
Two or four wire selectable ohms measurement
Display nulling and ohms null
Selectable measurement speed
Touch hold mode - holds onto a stable reading until updated
500 point data logger with timer
Temperature measurement for PT100 or PT1000 sensors
Wide range of computing functions e.g. Ax + B
External input/output remote triggering
Closed case calibration
USB interface standard (1908 & 1908P) plus RS232, LAN/LXI
Kensington security slot incorporated
Dimensions 250 x 97 x 295 mm
Weight 3.2 kg
Supplied with
IVI driver, LV/CVI driver, USB driver
Standards
EN61010-1, EN61010-2-030 & EN61010-2-033, EN61326-1 EMC