Techniniai dokumentai
Specifikacijos
Markė
Roxburgh EMCVaristor Voltage
24V
Maximum AC Voltage Rating
30V
Maximum DC Voltage Rating
38V
Medžiaga
Metal
Energy
8.8J
Serija
DVS
Maximum Surge Current
1000A
Ilgis
75mm
Gylis
52.5mm
Thickness
12.5mm
Matmenys
75 x 52.5 x 12.5mm
Kilmės šalis
United Kingdom
Produkto aprašymas
MOV Module, DVS Series
Modular slim-line transient voltage suppressors designed to snap-fit directly onto top hat profile DIN rails.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Sandėlio informacija laikinai nepasiekiama.
Patikrinkite dar kartą.
€ 56,52
už 1 vnt. (be PVM)
€ 68,39
už 1 vnt. (su PVM)
1
€ 56,52
už 1 vnt. (be PVM)
€ 68,39
už 1 vnt. (su PVM)
1
Pirkti dideliais kiekiais
kiekis | Vieneto kaina |
---|---|
1 - 4 | € 56,52 |
5 - 9 | € 54,15 |
10 - 24 | € 50,82 |
25 - 49 | € 49,40 |
50+ | € 47,50 |
Techniniai dokumentai
Specifikacijos
Markė
Roxburgh EMCVaristor Voltage
24V
Maximum AC Voltage Rating
30V
Maximum DC Voltage Rating
38V
Medžiaga
Metal
Energy
8.8J
Serija
DVS
Maximum Surge Current
1000A
Ilgis
75mm
Gylis
52.5mm
Thickness
12.5mm
Matmenys
75 x 52.5 x 12.5mm
Kilmės šalis
United Kingdom
Produkto aprašymas
MOV Module, DVS Series
Modular slim-line transient voltage suppressors designed to snap-fit directly onto top hat profile DIN rails.
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.