RS PRO Signal Conditioner, Current, Voltage Input, Relay Output, 230V ac Supply

RS Stock No.: 466-2400Brand: RS PRO
brand-logo
View all in Signal Conditioners

Technical Document

Specifications

Brand

RS Pro

Module Type

Trip Amplifier

Input Signal Type

Current, Voltage

Output Signal Type

Relay

Input Range

4 → 20mA

Supply Voltage

230V ac

Mounting Type

DIN Rail Mount

Operating Temperature Range

0 → +45°C

Series

BD

Minimum Operating Temperature

0°C

Maximum Operating Temperature

+45°C

Termination

Screw

Country of Origin

United Kingdom

Product details

BD120 Dual Level Trip Amplifier

RS Pro dual level trip amplifiers operate from a single process input, with a dual trip action. This output can be arranged so that the alarm condition is triggered either above or below the defined set point. The relay can also be configured for a Fail-Safe (energised in the stable state to de-energise in the alarm state) or Non-Fail Safe (de-energised in the stable state to energise in the alarm state) operation.

2 x SPCO relay (max. 60W load) output
High trip/low trip (user-configurable); fail-safe design (HLFS)
Adjustable set points
Bi-colour LED trip status indication: Green LED indicates stable state; red LED indicates alarm state

€ 232.00

€ 232.00 Each (Exc. Vat)

€ 280.72

€ 280.72 Each (inc. VAT)

RS PRO Signal Conditioner, Current, Voltage Input, Relay Output, 230V ac Supply
sticker-462

€ 232.00

€ 232.00 Each (Exc. Vat)

€ 280.72

€ 280.72 Each (inc. VAT)

RS PRO Signal Conditioner, Current, Voltage Input, Relay Output, 230V ac Supply

Stock information temporarily unavailable.

sticker-462

Stock information temporarily unavailable.

Technical Document

Specifications

Brand

RS Pro

Module Type

Trip Amplifier

Input Signal Type

Current, Voltage

Output Signal Type

Relay

Input Range

4 → 20mA

Supply Voltage

230V ac

Mounting Type

DIN Rail Mount

Operating Temperature Range

0 → +45°C

Series

BD

Minimum Operating Temperature

0°C

Maximum Operating Temperature

+45°C

Termination

Screw

Country of Origin

United Kingdom

Product details

BD120 Dual Level Trip Amplifier

RS Pro dual level trip amplifiers operate from a single process input, with a dual trip action. This output can be arranged so that the alarm condition is triggered either above or below the defined set point. The relay can also be configured for a Fail-Safe (energised in the stable state to de-energise in the alarm state) or Non-Fail Safe (de-energised in the stable state to energise in the alarm state) operation.

2 x SPCO relay (max. 60W load) output
High trip/low trip (user-configurable); fail-safe design (HLFS)
Adjustable set points
Bi-colour LED trip status indication: Green LED indicates stable state; red LED indicates alarm state