PR Electronics 2 Channel Galvanic Barrier, Pulse Isolator, NAMUR Sensor, Switch Input, NPN, Relay Output, ATEX

RS kodas: 796-6979Gamintojas: PR ElectronicsGamintojo kodas: 5202B2
brand-logo

Techniniai dokumentai

Specifikacijos

Number of Channels

2

Module Type

Pulse Isolator

Barrier Type

Galvanic Barrier

Output Signal Type

NPN, Relay

Maximum Voltage

250V ac

Hazardous Area Certification

ATEX

Input Signal Type

NAMUR Sensor, Switch

Supply Voltage

19.2 → 300 V dc, 21.6 → 253V ac

Minimali darbinė temperatūra

-20°C

Maksimali darbinė temperatūra

+60°C

Safety Current Maximum

400mA

Safety Voltage Maximum

250 V ac

Serija

5200

Operating Temperature Range

-20 → +60°C

Kilmės šalis

Denmark

Produkto aprašymas

PR Electronics 5202B Ex Pulse Isolator

PR Electronics 5202B pulse isolator for transmission of signals to the safe area from NAMUR sensors installed in hazardous areas. This signal conditioning isolator measures one or more pulse inputs and provides an identical number of isolated pulse outputs. The PR 5202B uses transformer and optical isolation techniques to provide 3.75 kVac galvanic isolation between the input, output and power terminals. The high level of electrical isolation means that input pulses sensed at the 5202B are not electrically connected to the output pulse. The 5202B has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Besides providing isolation, the PR 5202B is a barrier. This means that the module can make an intrinsically safe measurement of contacts and NAMUR sensors mounted in a zone 0/ Division 1 explosion hazard area. The PR 5202B limits the level of energy present at the contact or the NAMUR sensor to a low intrinsically safe level, thereby preventing ignition of a flammable atmosphere around the sensor – even if the sensor or the cable is damaged.

PR Electronics - Ex Interfaces

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more

Sandėlio informacija laikinai nepasiekiama.

Patikrinkite dar kartą.

Sandėlio informacija laikinai nepasiekiama.

€ 267,75

už 1 vnt. (be PVM)

€ 323,98

už 1 vnt. (su PVM)

PR Electronics 2 Channel Galvanic Barrier, Pulse Isolator, NAMUR Sensor, Switch Input, NPN, Relay Output, ATEX
sticker-462

€ 267,75

už 1 vnt. (be PVM)

€ 323,98

už 1 vnt. (su PVM)

PR Electronics 2 Channel Galvanic Barrier, Pulse Isolator, NAMUR Sensor, Switch Input, NPN, Relay Output, ATEX
Sandėlio informacija laikinai nepasiekiama.
sticker-462

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more

Techniniai dokumentai

Specifikacijos

Number of Channels

2

Module Type

Pulse Isolator

Barrier Type

Galvanic Barrier

Output Signal Type

NPN, Relay

Maximum Voltage

250V ac

Hazardous Area Certification

ATEX

Input Signal Type

NAMUR Sensor, Switch

Supply Voltage

19.2 → 300 V dc, 21.6 → 253V ac

Minimali darbinė temperatūra

-20°C

Maksimali darbinė temperatūra

+60°C

Safety Current Maximum

400mA

Safety Voltage Maximum

250 V ac

Serija

5200

Operating Temperature Range

-20 → +60°C

Kilmės šalis

Denmark

Produkto aprašymas

PR Electronics 5202B Ex Pulse Isolator

PR Electronics 5202B pulse isolator for transmission of signals to the safe area from NAMUR sensors installed in hazardous areas. This signal conditioning isolator measures one or more pulse inputs and provides an identical number of isolated pulse outputs. The PR 5202B uses transformer and optical isolation techniques to provide 3.75 kVac galvanic isolation between the input, output and power terminals. The high level of electrical isolation means that input pulses sensed at the 5202B are not electrically connected to the output pulse. The 5202B has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
Besides providing isolation, the PR 5202B is a barrier. This means that the module can make an intrinsically safe measurement of contacts and NAMUR sensors mounted in a zone 0/ Division 1 explosion hazard area. The PR 5202B limits the level of energy present at the contact or the NAMUR sensor to a low intrinsically safe level, thereby preventing ignition of a flammable atmosphere around the sensor – even if the sensor or the cable is damaged.

PR Electronics - Ex Interfaces

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more