Markė

Parker

Maximum Time

30s

Minimum Time

0.1s

Maksimali darbinė temperatūra

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimali darbinė temperatūra

-15°C

Produkto aprašymas

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.

Sandėlio informacija laikinai nepasiekiama.

Patikrinkite dar kartą.

Sandėlio informacija laikinai nepasiekiama.

€ 319,20

už 1 vnt. (be PVM)

€ 386,23

už 1 vnt. (su PVM)

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max
sticker-462

€ 319,20

už 1 vnt. (be PVM)

€ 386,23

už 1 vnt. (su PVM)

Parker PRT series 0.1s to 30s Pneumatic Timer, 8 bar max
Sandėlio informacija laikinai nepasiekiama.
sticker-462

Pirkti dideliais kiekiais

kiekisVieneto kaina
1 - 4€ 319,20
5+€ 306,60

Techniniai dokumentai

Specifikacijos

Markė

Parker

Maximum Time

30s

Minimum Time

0.1s

Maksimali darbinė temperatūra

+60°C

Manufacturer Series

PRT

Minimum Operating Pressure

3bar

Maximum Operating Pressure

8 bar

Minimali darbinė temperatūra

-15°C

Produkto aprašymas

Timer Module

A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.

Logic Systems

Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.