Techniniai dokumentai
Specifikacijos
Markė
MyrraSecondary Voltage Rating
3.3 → 6V ac
Primary Voltage Rating
85 → 265V ac
Galingumas
3.1W
Number of Outputs
1
Tvirtinimo tipas
PCB Mount
Application
Flyback
Inductance
2.1mH
Secondary Current
1.5A
Ilgis
18mm
Plotis
16mm
Gylis
17.5mm
Matmenys
18 x 16 x 17.5mm
Core Type
Laminated
Minimum Operating Frequency
50Hz
Construction
CEI335, CEI61558, CEI950
Number of Phases
1
Maximum Temperature
+60°C
Maximum Operating Frequency
60Hz
Kilmės šalis
France
Produkto aprašymas
Transformers for 1 → 9 W TINYSwitch II circuits
Standards
IEC 950, IEC 61558 for reinforced insulation
Open Frame - Laminated
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.
Sandėlio informacija laikinai nepasiekiama.
Patikrinkite dar kartą.
€ 7,32
€ 7,32 už 1 vnt. (be PVM)
€ 8,86
€ 8,86 už 1 vnt. (su PVM)
1

€ 7,32
€ 7,32 už 1 vnt. (be PVM)
€ 8,86
€ 8,86 už 1 vnt. (su PVM)
1

Techniniai dokumentai
Specifikacijos
Markė
MyrraSecondary Voltage Rating
3.3 → 6V ac
Primary Voltage Rating
85 → 265V ac
Galingumas
3.1W
Number of Outputs
1
Tvirtinimo tipas
PCB Mount
Application
Flyback
Inductance
2.1mH
Secondary Current
1.5A
Ilgis
18mm
Plotis
16mm
Gylis
17.5mm
Matmenys
18 x 16 x 17.5mm
Core Type
Laminated
Minimum Operating Frequency
50Hz
Construction
CEI335, CEI61558, CEI950
Number of Phases
1
Maximum Temperature
+60°C
Maximum Operating Frequency
60Hz
Kilmės šalis
France
Produkto aprašymas
Transformers for 1 → 9 W TINYSwitch II circuits
Standards
IEC 950, IEC 61558 for reinforced insulation
Open Frame - Laminated