Technical Document
Specifications
Brand
LEMProduct Type
Current Transformer
Series
HASS
Terminal Type
Wire
Primary Current
500A
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
85°C
Length
30mm
Depth
32.4mm
Weight
55g
Standards/Approvals
UL, IEC 61010-1, EN 50178, CE
Width
40mm
Mount Type
Panel
Minimum Operating Frequency
240kHz
Bore Size
20mm
Supply Voltage
5V
Product details
HASS Series
Open loop current transducer with Hall effect measuring principle
For measuring DC, AC and pulse currents
With galvanic separation between primary and secondary circuits
Unipolar voltage supply
Fixed offset voltage with corresponding amplification
Housing made from insulating, self-extinguishing material UL94-V0
Approvals
CE
Stock information temporarily unavailable.
€ 23.27
€ 23.27 Each (Exc. Vat)
€ 28.16
€ 28.16 Each (inc. VAT)
1

€ 23.27
€ 23.27 Each (Exc. Vat)
€ 28.16
€ 28.16 Each (inc. VAT)
Stock information temporarily unavailable.
1

Technical Document
Specifications
Brand
LEMProduct Type
Current Transformer
Series
HASS
Terminal Type
Wire
Primary Current
500A
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
85°C
Length
30mm
Depth
32.4mm
Weight
55g
Standards/Approvals
UL, IEC 61010-1, EN 50178, CE
Width
40mm
Mount Type
Panel
Minimum Operating Frequency
240kHz
Bore Size
20mm
Supply Voltage
5V
Product details
HASS Series
Open loop current transducer with Hall effect measuring principle
For measuring DC, AC and pulse currents
With galvanic separation between primary and secondary circuits
Unipolar voltage supply
Fixed offset voltage with corresponding amplification
Housing made from insulating, self-extinguishing material UL94-V0
Approvals
CE