Fluke 355 Clamp Meter, 2000 A 2000 A 1000 V 600 V ac CAT IV, CAT III Non-Contact Voltage Detector

RS Stock No.: 413-784Brand: FlukeManufacturers Part No.: FLUKE 355
brand-logo
View all in Clamp Meters

Technical Document

Specifications

Brand

Fluke

Product Type

Clamp Meter

Maximum DC Current Measurement

2000A

Resistance Resolution

100mΩ

Maximum AC Voltage Measurement

600V ac

Maximum DC Voltage Measurement

1000V

Maximum Resistance Measurement

400kΩ

Model Number

355

Maximum Jaw Opening

58 mm

AC Voltage Resolution

1mV

AC Voltage Accuracy

±1 % rdg + 5 Digits

Minimum Operating Temperature

0°C

AC Current Resolution

10mA

Resistance Measurement Accuracy

1.5 % rdg + 5 Digits Ω (all ranges)

DC Current Resolution

10mA

DC Current Accuracy

±1.5 % rdg + 5 Digits

AC Current Accuracy

±1.5 % rdg + 5 Digits

DC Voltage Resolution

1 mV

Clamp Meter Type

AC/DC Clamp Meter

DC Voltage Accuracy

±1 % rdg + 5 Digits

Maximum Operating Temperature

50°C

Width

98 mm

Height

52mm

Length

300mm

Weight

814g

Standards/Approvals

RoHS

True RMS

Yes

Functions Measured

AC Voltage, DC Current, DC Voltage, Frequency, Continuity, AC Current, Resistance

Maximum Conductor Size

58 mm

Maximum AC Current Measurement

2000A

Non-Contact Voltage Detector

Yes

Calibrated

RSCAL

Battery Life

100h

Safety Category Level

CAT IV, CAT III

Battery Type

AA

Display Type

LCD

Safety Category Voltage

1000V

Power Source

Battery

Country of Origin

China

Product details

Fluke 355 True-RMS, 2000A Clamp Meter


Confidently take reliable readings with the True-rms, Fluke 355 digital clamp meter; the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

Features:

4000 count backlit display
True-RMS AC + DC current & voltage measurement
True RMS crest factor = 2.4
Motor inrush current measurement
Min/Max/Average recording mode
Frequency Measurement
Voltage AC/DC
Resistance measurement
Continuity measurement with beeper
58mm dia conductor jaw capacity
Safety to EN61010 CAT IV 600 V, CAT III 1000 V

Supplied with

C43 soft case, 6 AA alkaline batteries, TL224 1.5m silicone test leads, TP2 slim reach probes (2 mm), AC285 crocodile clips and users manual

Stock information temporarily unavailable.

€ 1,325.00

€ 1,325.00 Each (Exc. Vat)

€ 1,603.25

€ 1,603.25 Each (inc. VAT)

Fluke 355 Clamp Meter, 2000 A 2000 A 1000 V 600 V ac CAT IV, CAT III Non-Contact Voltage Detector

Calibration type

sticker-462

€ 1,325.00

€ 1,325.00 Each (Exc. Vat)

€ 1,603.25

€ 1,603.25 Each (inc. VAT)

Fluke 355 Clamp Meter, 2000 A 2000 A 1000 V 600 V ac CAT IV, CAT III Non-Contact Voltage Detector

Stock information temporarily unavailable.

Calibration type

sticker-462

Technical Document

Specifications

Brand

Fluke

Product Type

Clamp Meter

Maximum DC Current Measurement

2000A

Resistance Resolution

100mΩ

Maximum AC Voltage Measurement

600V ac

Maximum DC Voltage Measurement

1000V

Maximum Resistance Measurement

400kΩ

Model Number

355

Maximum Jaw Opening

58 mm

AC Voltage Resolution

1mV

AC Voltage Accuracy

±1 % rdg + 5 Digits

Minimum Operating Temperature

0°C

AC Current Resolution

10mA

Resistance Measurement Accuracy

1.5 % rdg + 5 Digits Ω (all ranges)

DC Current Resolution

10mA

DC Current Accuracy

±1.5 % rdg + 5 Digits

AC Current Accuracy

±1.5 % rdg + 5 Digits

DC Voltage Resolution

1 mV

Clamp Meter Type

AC/DC Clamp Meter

DC Voltage Accuracy

±1 % rdg + 5 Digits

Maximum Operating Temperature

50°C

Width

98 mm

Height

52mm

Length

300mm

Weight

814g

Standards/Approvals

RoHS

True RMS

Yes

Functions Measured

AC Voltage, DC Current, DC Voltage, Frequency, Continuity, AC Current, Resistance

Maximum Conductor Size

58 mm

Maximum AC Current Measurement

2000A

Non-Contact Voltage Detector

Yes

Calibrated

RSCAL

Battery Life

100h

Safety Category Level

CAT IV, CAT III

Battery Type

AA

Display Type

LCD

Safety Category Voltage

1000V

Power Source

Battery

Country of Origin

China

Product details

Fluke 355 True-RMS, 2000A Clamp Meter


Confidently take reliable readings with the True-rms, Fluke 355 digital clamp meter; the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.

Features:

4000 count backlit display
True-RMS AC + DC current & voltage measurement
True RMS crest factor = 2.4
Motor inrush current measurement
Min/Max/Average recording mode
Frequency Measurement
Voltage AC/DC
Resistance measurement
Continuity measurement with beeper
58mm dia conductor jaw capacity
Safety to EN61010 CAT IV 600 V, CAT III 1000 V

Supplied with

C43 soft case, 6 AA alkaline batteries, TL224 1.5m silicone test leads, TP2 slim reach probes (2 mm), AC285 crocodile clips and users manual