DehnSuppressor Type
Surge Arrester
Maximum Voltage Rating
240 V
Maximum Surge Current
40kA
Serija
ESB2
Ilgis
125mm
Gylis
83mm
Aukštis
210mm
Matmenys
125 x 83 x 210mm
Kilmės šalis
Germany
Produkto aprašymas
ESB 2 Boxed DSP DEHNguard Modular Surge Arrestors
Transient Voltage Suppressors (Modules,Industrial)
Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.
Sandėlio informacija laikinai nepasiekiama.
Patikrinkite dar kartą.
€ 135,85
už 1 vnt. (be PVM)
€ 164,38
už 1 vnt. (su PVM)
1
€ 135,85
už 1 vnt. (be PVM)
€ 164,38
už 1 vnt. (su PVM)
1
Pirkti dideliais kiekiais
kiekis | Vieneto kaina |
---|---|
1 - 9 | € 135,85 |
10 - 19 | € 131,10 |
20 - 24 | € 122,55 |
25 - 49 | € 117,80 |
50+ | € 115,90 |
Techniniai dokumentai
Specifikacijos
Markė
DehnSuppressor Type
Surge Arrester
Maximum Voltage Rating
240 V
Maximum Surge Current
40kA
Serija
ESB2
Ilgis
125mm
Gylis
83mm
Aukštis
210mm
Matmenys
125 x 83 x 210mm
Kilmės šalis
Germany
Produkto aprašymas
ESB 2 Boxed DSP DEHNguard Modular Surge Arrestors
Transient Voltage Suppressors (Modules,Industrial)
Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning activity and can reach up to 6000V, with current surges of up to 3000A. The maximum size of the voltage and current surges depends on the location within the buildings wiring system. BS6651:1999 Annex C which was replaced in August 2008 by BS EN 62305-4:2006 is complemented by BS EN 61643-11/12 and covers location categories and provides guidance on protection of electronic equipment. For mains power systems, Types I, II and III are used. Surge protection devices not designed to fit into these categories may only provide limited protection and the equipment they protect may suffer damage.