Dehn, DG Surge Protection Plug 255 V ac Maximum Voltage Rating 40kA Maximum Surge Current Surge Arrester Protection

RS kodas: 768-1776Gamintojas: DehnGamintojo kodas: DG MOD NPE
brand-logo
Žiūrėti viską Viršsrovių slopintuvai

Techniniai dokumentai

Specifikacijos

Markė

Dehn

Suppressor Type

Surge Arrester Protection Module

Maximum Voltage Rating

255 V ac

Tvirtinimo tipas

Plug In

Maximum Surge Current

40kA

Serija

DG

Ilgis

45mm

Gylis

18mm

Aukštis

51mm

Matmenys

45 x 18 x 51mm

Kilmės šalis

Germany

Produkto aprašymas

DEHNguard and DEHNrail Replacement Plugin Modules

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Sandėlio informacija laikinai nepasiekiama.

Patikrinkite dar kartą.

Sandėlio informacija laikinai nepasiekiama.

€ 141,55

už 1 vnt. (be PVM)

€ 171,28

už 1 vnt. (su PVM)

Dehn, DG Surge Protection Plug 255 V ac Maximum Voltage Rating 40kA Maximum Surge Current Surge Arrester Protection
sticker-462

€ 141,55

už 1 vnt. (be PVM)

€ 171,28

už 1 vnt. (su PVM)

Dehn, DG Surge Protection Plug 255 V ac Maximum Voltage Rating 40kA Maximum Surge Current Surge Arrester Protection
Sandėlio informacija laikinai nepasiekiama.
sticker-462

Pirkti dideliais kiekiais

kiekisVieneto kaina
1 - 4€ 141,55
5 - 9€ 135,85
10 - 19€ 129,20
20 - 29€ 117,80
30+€ 104,50

Techniniai dokumentai

Specifikacijos

Markė

Dehn

Suppressor Type

Surge Arrester Protection Module

Maximum Voltage Rating

255 V ac

Tvirtinimo tipas

Plug In

Maximum Surge Current

40kA

Serija

DG

Ilgis

45mm

Gylis

18mm

Aukštis

51mm

Matmenys

45 x 18 x 51mm

Kilmės šalis

Germany

Produkto aprašymas

DEHNguard and DEHNrail Replacement Plugin Modules

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.