Techniniai dokumentai
Specifikacijos
Markė
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
DPDT
Voltage Sensing Range
194 → 528 V
Voltage Sensitivity
Overvoltage, Undervoltage
Tvirtinimo tipas
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Serija
HWUA
Aukštis
92.6mm
Ilgis
69mm
Minimum Voltage Sensed
194 V
Operating Temperature Range
+50°C
Minimali darbinė temperatūra
-20°C
Plotis
35mm
Maksimali darbinė temperatūra
+50°C
Matmenys
69 x 35 x 92.6mm
Maximum Voltage Sensed
528V
Produkto aprašymas
Multi Function Phase Control Relays 35mm - C-Lynx
The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.
Sandėlio informacija laikinai nepasiekiama.
Patikrinkite dar kartą.
€ 240,35
už 1 vnt. (be PVM)
€ 290,82
už 1 vnt. (su PVM)
1
€ 240,35
už 1 vnt. (be PVM)
€ 290,82
už 1 vnt. (su PVM)
1
Pirkti dideliais kiekiais
kiekis | Vieneto kaina |
---|---|
1 - 4 | € 240,35 |
5 - 9 | € 224,20 |
10 - 24 | € 212,80 |
25 - 49 | € 200,45 |
50+ | € 189,05 |
Techniniai dokumentai
Specifikacijos
Markė
CrouzetMonitoring Application
Phase, Voltage
Electrical Phase
3
Contact Configuration
DPDT
Voltage Sensing Range
194 → 528 V
Voltage Sensitivity
Overvoltage, Undervoltage
Tvirtinimo tipas
DIN Rail
Phase Sensitivity
Phase Asymmetry, Phase Failure, Phase Sequence
Time Delay
0.1 → 10s
Serija
HWUA
Aukštis
92.6mm
Ilgis
69mm
Minimum Voltage Sensed
194 V
Operating Temperature Range
+50°C
Minimali darbinė temperatūra
-20°C
Plotis
35mm
Maksimali darbinė temperatūra
+50°C
Matmenys
69 x 35 x 92.6mm
Maximum Voltage Sensed
528V
Produkto aprašymas
Multi Function Phase Control Relays 35mm - C-Lynx
The HWUA 3 phase network control relay monitors:- The correct sequence of phases L1, L2, L3,- Total phase failure,- Undervoltage and overvoltage from 2% to 20% of Under Voltage Relay,- Asymmetry rate from 5% to 15% of Under Voltage Relay,- Faults are signalled via LEDs, distinguishing the origin of the fault. If a fault persists for longer than the threshold crossing delay configured by the operator, both output relays open and LED R is extinguished.