Techniniai dokumentai
Specifikacijos
Markė
BournsSuppressor Type
Photovoltaic Surge Protector
Maximum Voltage Rating
1200 V dc
Tvirtinimo tipas
DIN Rail
Maximum Surge Current
40kA
Serija
1420
Ilgis
54mm
Gylis
67mm
Aukštis
90mm
Matmenys
54 x 67 x 90mm
Minimali darbinė temperatūra
-50°C
Maksimali darbinė temperatūra
+85°C
Kilmės šalis
China
Produkto aprašymas
Bourns DC SPD for Photovoltaic applications
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Sandėlio informacija laikinai nepasiekiama.
Patikrinkite dar kartą.
€ 256,20
Each (In a Box of 3) (be PVM)
€ 310,002
Each (In a Box of 3) (su PVM)
3
€ 256,20
Each (In a Box of 3) (be PVM)
€ 310,002
Each (In a Box of 3) (su PVM)
3
Pirkti dideliais kiekiais
kiekis | Vieneto kaina | Per Dėžutė |
---|---|---|
3 - 12 | € 256,20 | € 768,60 |
15 - 27 | € 250,95 | € 752,85 |
30+ | € 246,75 | € 740,25 |
Techniniai dokumentai
Specifikacijos
Markė
BournsSuppressor Type
Photovoltaic Surge Protector
Maximum Voltage Rating
1200 V dc
Tvirtinimo tipas
DIN Rail
Maximum Surge Current
40kA
Serija
1420
Ilgis
54mm
Gylis
67mm
Aukštis
90mm
Matmenys
54 x 67 x 90mm
Minimali darbinė temperatūra
-50°C
Maksimali darbinė temperatūra
+85°C
Kilmės šalis
China
Produkto aprašymas
Bourns DC SPD for Photovoltaic applications
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.