Specifikacijos
Range
SmartGuard 600
Number of I/O
24
Number of Safety Inputs
16
Number of Safety Outputs
8
Safety Category
4
SIL
SIL 3
Supply Voltage
24 V dc
Contact Current Rating
500 mA
Matmenys
99 x 90.4 x 131.4 mm
Gylis
131.4mm
Ilgis
99mm
Plotis
90.4mm
Produkto aprašymas
Smartguard 600, Safety Controller, Base Unit
Designed for applications that have traditionally fallen between safety relays and safety PLCs, the SmartGuard 600 is a general purpose programmable safety controller for safety applications that require some complex logic - allowing for more advanced safety functionality. It features 16 safety-rated inputs, 8 safety-rated outputs, 4 pulse test sources, and a DeviceNet connection that supports both standard and CIP Safety communication. Configuration and programming is accomplished through the built-in USB port.
Approvals
c-UL-us, UL listed for Class 1 Division 2 Groups A, B, C, D Hazardous Locations; UL certified for Functional Safety. See UL File E256621; CE; C-Tick; TUV certified for functional safety up to SIL 3, Cat. 4; ODVA conformance tested to DeviceNet and DeviceNet Safety specifications
Standards
IEC61508 SIL3 and EN954-1 Cat.4
Sandėlio informacija laikinai nepasiekiama.
Patikrinkite dar kartą.
€ 4 417,50
už 1 vnt. (be PVM)
€ 5 345,18
už 1 vnt. (su PVM)
1
€ 4 417,50
už 1 vnt. (be PVM)
€ 5 345,18
už 1 vnt. (su PVM)
1
Techniniai dokumentai
Specifikacijos
Range
SmartGuard 600
Number of I/O
24
Number of Safety Inputs
16
Number of Safety Outputs
8
Safety Category
4
SIL
SIL 3
Supply Voltage
24 V dc
Contact Current Rating
500 mA
Matmenys
99 x 90.4 x 131.4 mm
Gylis
131.4mm
Ilgis
99mm
Plotis
90.4mm
Produkto aprašymas
Smartguard 600, Safety Controller, Base Unit
Designed for applications that have traditionally fallen between safety relays and safety PLCs, the SmartGuard 600 is a general purpose programmable safety controller for safety applications that require some complex logic - allowing for more advanced safety functionality. It features 16 safety-rated inputs, 8 safety-rated outputs, 4 pulse test sources, and a DeviceNet connection that supports both standard and CIP Safety communication. Configuration and programming is accomplished through the built-in USB port.
Approvals
c-UL-us, UL listed for Class 1 Division 2 Groups A, B, C, D Hazardous Locations; UL certified for Functional Safety. See UL File E256621; CE; C-Tick; TUV certified for functional safety up to SIL 3, Cat. 4; ODVA conformance tested to DeviceNet and DeviceNet Safety specifications
Standards
IEC61508 SIL3 and EN954-1 Cat.4