Omron PLC Expansion Module for Use with DRT2 Series, Analogue

RS Stock No.: 746-3073Brand: OmronManufacturers Part No.: DRT2DA02
brand-logo
View all in PLC Accessories

Technical Document

Specifications

Brand

Omron

Accessory Type

PLC Expansion Module

Number of Outputs

2

Output Type

Analogue

For Use With

DRT2 Series

Dimensions

115 x 53.1 x 49.7 mm

Product details

Analogue I/O Terminals

Performs calculations on analogue values within the slave Itself
Provides high resolution at 1/30,000 (full scale) and
support for a wide variety of data sampling
Equipped with the standard Smart Slave functions that provide powerful
preventative maintenance and troubleshooting capabilities
Sampling data can be analyzed internally to provide a low-cost scheduler
Function
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative
calculation function
Two I/O points can be allocated to any two of the following values: analogue
input, peak/bottom, top, valley, or rate-of-change. Values without an
allocated I/O point can be read with message communications

Omron DRT2 Temperature Input Terminals

€ 725.00

€ 725.00 Each (Exc. Vat)

€ 877.25

€ 877.25 Each (inc. VAT)

Omron PLC Expansion Module for Use with DRT2 Series, Analogue
sticker-462

€ 725.00

€ 725.00 Each (Exc. Vat)

€ 877.25

€ 877.25 Each (inc. VAT)

Omron PLC Expansion Module for Use with DRT2 Series, Analogue

Stock information temporarily unavailable.

sticker-462

Stock information temporarily unavailable.

Technical Document

Specifications

Brand

Omron

Accessory Type

PLC Expansion Module

Number of Outputs

2

Output Type

Analogue

For Use With

DRT2 Series

Dimensions

115 x 53.1 x 49.7 mm

Product details

Analogue I/O Terminals

Performs calculations on analogue values within the slave Itself
Provides high resolution at 1/30,000 (full scale) and
support for a wide variety of data sampling
Equipped with the standard Smart Slave functions that provide powerful
preventative maintenance and troubleshooting capabilities
Sampling data can be analyzed internally to provide a low-cost scheduler
Function
Equipped with functions such as the scaling function, peak/bottom hold;
top/valley hold; comparator function, cumulative counter, and derivative
calculation function
Two I/O points can be allocated to any two of the following values: analogue
input, peak/bottom, top, valley, or rate-of-change. Values without an
allocated I/O point can be read with message communications

Omron DRT2 Temperature Input Terminals