Pepperl + Fuchs 2 Channel Zener Barrier, ATEX

RS kodas: 280-6608Gamintojas: Pepperl + FuchsGamintojo kodas: Z 960
brand-logo

Techniniai dokumentai

Specifikacijos

Number of Channels

2

Module Type

Zener Barrier

Barrier Type

Zener Barrier

Maximum Voltage

250V

Hazardous Area Certification

ATEX

Safety Current Resistance

64Ω

Maksimali darbinė temperatūra

+60°C

Supply Voltage

10V ac

Maximum Current

203mA

Minimali darbinė temperatūra

-20°C

Safety Current Maximum

203mA

Safety Voltage Maximum

250 V

Operating Temperature Range

-20 → +60°C

Kilmės šalis

Indonesia

Produkto aprašymas

Z960 Dual Channel AC Powered

Using a dual channel barrier impedes a direct grounding of the intrinsically safe circuit. The ground is only made in the event of a failure, if the zener diodes conduct. This circuit also suppresses influences of external circuits.,Typical application - thermocouples

Isolation Barriers

Pepperl+Fuchs shunt zener diode barriers are for use as safety interfaces between intrinsically safe and non-intrinsically safe circuits. They are manufactured from Makrolon® and designed to conduct electrical signals - in either direction - between safe and hazardous areas and to limit the amount of energy which can be transferred from a safe to a hazardous area in the event of fault conditions occurring in the safe area. All systems shown are licensed for [EEx ia] IIC Class 1, Div1, Groups A-G

Sandėlio informacija laikinai nepasiekiama.

Patikrinkite dar kartą.

Sandėlio informacija laikinai nepasiekiama.

€ 157,70

už 1 vnt. (be PVM)

€ 190,82

už 1 vnt. (su PVM)

Pepperl + Fuchs 2 Channel Zener Barrier, ATEX
sticker-462

€ 157,70

už 1 vnt. (be PVM)

€ 190,82

už 1 vnt. (su PVM)

Pepperl + Fuchs 2 Channel Zener Barrier, ATEX
Sandėlio informacija laikinai nepasiekiama.
sticker-462

Techniniai dokumentai

Specifikacijos

Number of Channels

2

Module Type

Zener Barrier

Barrier Type

Zener Barrier

Maximum Voltage

250V

Hazardous Area Certification

ATEX

Safety Current Resistance

64Ω

Maksimali darbinė temperatūra

+60°C

Supply Voltage

10V ac

Maximum Current

203mA

Minimali darbinė temperatūra

-20°C

Safety Current Maximum

203mA

Safety Voltage Maximum

250 V

Operating Temperature Range

-20 → +60°C

Kilmės šalis

Indonesia

Produkto aprašymas

Z960 Dual Channel AC Powered

Using a dual channel barrier impedes a direct grounding of the intrinsically safe circuit. The ground is only made in the event of a failure, if the zener diodes conduct. This circuit also suppresses influences of external circuits.,Typical application - thermocouples

Isolation Barriers

Pepperl+Fuchs shunt zener diode barriers are for use as safety interfaces between intrinsically safe and non-intrinsically safe circuits. They are manufactured from Makrolon® and designed to conduct electrical signals - in either direction - between safe and hazardous areas and to limit the amount of energy which can be transferred from a safe to a hazardous area in the event of fault conditions occurring in the safe area. All systems shown are licensed for [EEx ia] IIC Class 1, Div1, Groups A-G