Techniniai dokumentai
Specifikacijos
Dimensions (L x W x H)
94 x 94 x45mm
Minimali darbinė temperatūra
-40°C
Maksimali darbinė temperatūra
+105°C
Leakage Current
0.01 CV or 3 μA @ 2 min
USB Version
USB2.0
Lead Pitch
3.5mm
Diameter
8mm
Lifetime
7000h
Tolerancija
±20%
Voltage
35V dc
Aukštis
11.5mm
Capacitance
220µF
Equivalent Series Resistance
130mΩ
Serija
NRE-JL
Markė
NIC ComponentsRipple Current
640mA
Matmenys
8 (Dia.) x 11.5mm
Kilmės šalis
Japan
Produkto aprašymas
Ty-Fast® Flame-retardant Cable Ties, White
Ty-Fast® flame-retardant cable ties are manufactured in flame-retardant Nylon 6.6 which meets the UL 94 V-0 flammability rating. They are particularly well-suited for use in public areas and highly trafficked areas requiring low flammability and low smoke spread, where evacuation will be a design criterion. Examples include mass transit system vehicles and cruise liners (passenger and crew compartments), offshore structures such as oil & gas rigs, and civil engineering infrastructure works including tunnels, transport interchanges and all areas of public assembly such as concourses, shopping malls and sports venues.
Sandėlio informacija laikinai nepasiekiama.
Patikrinkite dar kartą.
€ 0,171
Each (In a Bag of 200) (be PVM)
€ 0,207
Each (In a Bag of 200) (su PVM)
200
€ 0,171
Each (In a Bag of 200) (be PVM)
€ 0,207
Each (In a Bag of 200) (su PVM)
200
Techniniai dokumentai
Specifikacijos
Dimensions (L x W x H)
94 x 94 x45mm
Minimali darbinė temperatūra
-40°C
Maksimali darbinė temperatūra
+105°C
Leakage Current
0.01 CV or 3 μA @ 2 min
USB Version
USB2.0
Lead Pitch
3.5mm
Diameter
8mm
Lifetime
7000h
Tolerancija
±20%
Voltage
35V dc
Aukštis
11.5mm
Capacitance
220µF
Equivalent Series Resistance
130mΩ
Serija
NRE-JL
Markė
NIC ComponentsRipple Current
640mA
Matmenys
8 (Dia.) x 11.5mm
Kilmės šalis
Japan
Produkto aprašymas
Ty-Fast® Flame-retardant Cable Ties, White
Ty-Fast® flame-retardant cable ties are manufactured in flame-retardant Nylon 6.6 which meets the UL 94 V-0 flammability rating. They are particularly well-suited for use in public areas and highly trafficked areas requiring low flammability and low smoke spread, where evacuation will be a design criterion. Examples include mass transit system vehicles and cruise liners (passenger and crew compartments), offshore structures such as oil & gas rigs, and civil engineering infrastructure works including tunnels, transport interchanges and all areas of public assembly such as concourses, shopping malls and sports venues.