Techniniai Dokumentai
Specifikacijos
Markė
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
48V dc
Number of Outputs
2
Mount Type
Panel
Power
400W
Minimali darbinė temperatūra
-20°C
SMPS Output Current
5.21A
Maksimali darbinė temperatūra
70°C
Gylis
198mm
Weight
440g
Standards/Approvals
IEC 61000-4-8 (lv 4), IEC/UL/CSA/EN 62368-1, IEC 61000-4-4 (lv 3), IEC 61000-4-5 (lv 3,4), IEC 61000-4-6 (lv 3), CE, EN 55022-B, FCC-B, IEC 61000-4-11, IEC 61000-4-2 (lv 2,3), IEC 61000-4-3 (lv3)
Plotis
128mm
Ilgis
198mm
Efficiency
90%
Maximum Input Voltage
264V ac
Serija
CUS400M
Output Current
5.21A
Hazardous Area Certification
No
Minimum Input Voltage
85V ac
Kilmės šalis
United Kingdom
Produkto Aprašymas
The TDK-Lambda compact CUS400M is packaged in the industry standard 3x5 footprint. The series can deliver 400W with forced air or 250W when convection cooled with a 400W peak power for extended periods of time (minutes). Cooling is also assisted via conduction through the base into the equipment chassis. With Medical & ITE certifications, the units can be used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. Options include a standby voltage, signalling and multiple case options.
Sandėlio informacija laikinai nepasiekiama.
€ 300,00
€ 300,00 už 1 vnt. (be PVM)
€ 363,00
€ 363,00 už 1 vnt. (su PVM)
1

€ 300,00
€ 300,00 už 1 vnt. (be PVM)
€ 363,00
€ 363,00 už 1 vnt. (su PVM)
Sandėlio informacija laikinai nepasiekiama.
1

Techniniai Dokumentai
Specifikacijos
Markė
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
48V dc
Number of Outputs
2
Mount Type
Panel
Power
400W
Minimali darbinė temperatūra
-20°C
SMPS Output Current
5.21A
Maksimali darbinė temperatūra
70°C
Gylis
198mm
Weight
440g
Standards/Approvals
IEC 61000-4-8 (lv 4), IEC/UL/CSA/EN 62368-1, IEC 61000-4-4 (lv 3), IEC 61000-4-5 (lv 3,4), IEC 61000-4-6 (lv 3), CE, EN 55022-B, FCC-B, IEC 61000-4-11, IEC 61000-4-2 (lv 2,3), IEC 61000-4-3 (lv3)
Plotis
128mm
Ilgis
198mm
Efficiency
90%
Maximum Input Voltage
264V ac
Serija
CUS400M
Output Current
5.21A
Hazardous Area Certification
No
Minimum Input Voltage
85V ac
Kilmės šalis
United Kingdom
Produkto Aprašymas
The TDK-Lambda compact CUS400M is packaged in the industry standard 3x5 footprint. The series can deliver 400W with forced air or 250W when convection cooled with a 400W peak power for extended periods of time (minutes). Cooling is also assisted via conduction through the base into the equipment chassis. With Medical & ITE certifications, the units can be used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. Options include a standby voltage, signalling and multiple case options.