Techniniai Dokumentai
Specifikacijos
Markė
RS ProProduct Type
Chassis Mount Transformer
Primary Voltage
230 V ac
Secondary Voltage
9 V ac
Number of Outputs
2
Power
50VA
Minimali darbinė temperatūra
-30°C
Maksimali darbinė temperatūra
70°C
Minimum Operating Frequency
50Hz
Ilgis
79mm
Gylis
65mm
Weight
1kg
Plotis
62mm
Maximum Operating Frequency
60Hz
Standards/Approvals
IEC 61558-2-6
Kilmės šalis
Poland
Produkto Aprašymas
Chassis Mount Clamp & Frame Construction 115/230Vac Primary Transformer
Features and Benefits
"Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Two hole fixing wrap-over clamps 6VA to 50VA
Multi-hole frame fixing 100VA
Solder tag terminations
Optional terminal shrouds
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742"
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.
Suitable transformer shrouds: 6VA = 503-912 ; 12 & 20VA = 504-004 ; 50, 75 & 100VA = 503-928
BS3535; EN 60 742
Sandėlio informacija laikinai nepasiekiama.
€ 47,00
€ 47,00 už 1 vnt. (be PVM)
€ 56,87
€ 56,87 už 1 vnt. (su PVM)
1

€ 47,00
€ 47,00 už 1 vnt. (be PVM)
€ 56,87
€ 56,87 už 1 vnt. (su PVM)
Sandėlio informacija laikinai nepasiekiama.
1

| kiekis | Vieneto kaina |
|---|---|
| 1 - 24 | € 47,00 |
| 25+ | € 40,60 |
Techniniai Dokumentai
Specifikacijos
Markė
RS ProProduct Type
Chassis Mount Transformer
Primary Voltage
230 V ac
Secondary Voltage
9 V ac
Number of Outputs
2
Power
50VA
Minimali darbinė temperatūra
-30°C
Maksimali darbinė temperatūra
70°C
Minimum Operating Frequency
50Hz
Ilgis
79mm
Gylis
65mm
Weight
1kg
Plotis
62mm
Maximum Operating Frequency
60Hz
Standards/Approvals
IEC 61558-2-6
Kilmės šalis
Poland
Produkto Aprašymas
Chassis Mount Clamp & Frame Construction 115/230Vac Primary Transformer
Features and Benefits
"Double section bobbin construction
Fully shrouded bobbins
Full varnish impregnation
Two hole fixing wrap-over clamps 6VA to 50VA
Multi-hole frame fixing 100VA
Solder tag terminations
Optional terminal shrouds
100% electrical and flash tested
Tested in accordance with BS3535 and EN 60 742"
Chassis mounting mains transformers with twin 115Va.c. 50/60Hz primary windings which may be connected in series for 230V or parallel for 115V operation. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.
Suitable transformer shrouds: 6VA = 503-912 ; 12 & 20VA = 504-004 ; 50, 75 & 100VA = 503-928
BS3535; EN 60 742