Techniniai Dokumentai
Specifikacijos
Markė
RittalProduct Type
Fire Alarm Control Panel
Auto Reset
No
Silent Maintenance Testing
No
Serija
DK
Standards/Approvals
EAC
Kilmės šalis
Germany
Produkto Aprašymas
This fire alarm control panel is designed for early fire detection. Incorporating an innovative smoke extraction system, it fits into a compact 482.6mm (19) subrack with a height of just 1U. The unit is beneficial for protecting environments that necessitate stringent fire safety measures.
The panel employs two optical smoke detectors: one triggers a pre-alarm upon detecting smoke while the other activates the main alarm. This dual system provides a reliable early warning mechanism for fire safety.
The unit operates within a voltage range of 100V to 240V, accommodating both 50Hz and 60Hz power supplies for versatile installation options.
This device is designed to function optimally in environments ranging from +10°C to +40°C, with a broader operating range extending from -20°C to +65°C for diverse applications.
The panel features multiple relay outputs to indicate pre-alarm, main alarm, and collective faults, ensuring comprehensive monitoring of fire safety conditions.
Sandėlio informacija laikinai nepasiekiama.
€ 6 780,00
€ 6 780,00 už 1 vnt. (be PVM)
€ 8 203,80
€ 8 203,80 už 1 vnt. (su PVM)
1

€ 6 780,00
€ 6 780,00 už 1 vnt. (be PVM)
€ 8 203,80
€ 8 203,80 už 1 vnt. (su PVM)
Sandėlio informacija laikinai nepasiekiama.
1

Techniniai Dokumentai
Specifikacijos
Markė
RittalProduct Type
Fire Alarm Control Panel
Auto Reset
No
Silent Maintenance Testing
No
Serija
DK
Standards/Approvals
EAC
Kilmės šalis
Germany
Produkto Aprašymas
This fire alarm control panel is designed for early fire detection. Incorporating an innovative smoke extraction system, it fits into a compact 482.6mm (19) subrack with a height of just 1U. The unit is beneficial for protecting environments that necessitate stringent fire safety measures.
The panel employs two optical smoke detectors: one triggers a pre-alarm upon detecting smoke while the other activates the main alarm. This dual system provides a reliable early warning mechanism for fire safety.
The unit operates within a voltage range of 100V to 240V, accommodating both 50Hz and 60Hz power supplies for versatile installation options.
This device is designed to function optimally in environments ranging from +10°C to +40°C, with a broader operating range extending from -20°C to +65°C for diverse applications.
The panel features multiple relay outputs to indicate pre-alarm, main alarm, and collective faults, ensuring comprehensive monitoring of fire safety conditions.