Specifikacijos
Markė
Phoenix ContactCoil Voltage
24V dc
Tvirtinimo tipas
DIN Rail
Contact Configuration
4NO/2NC
Switching Current
6A
Coil Power
1.25W
Maximum Switching Current AC
6 A
Maximum Switching Current (AC)
6 A
Maximum Switching Current DC
6 A
Maximum Switching Current (DC)
6 A
Maximum Switching Voltage DC
250V
Maximum Switching Voltage (DC)
250V
Maximum Switching Voltage AC
250V
Maximum Switching Voltage (AC)
250V
Terminal Type
Screw
Approvals
CE, cULus
Standards Met
cUL Listed, CULus, UL Listed
Maksimali darbinė temperatūra
+55°C
Isolation Coil To Contact
4kV
Gylis
55mm
Aukštis
111mm
Ilgis
40mm
Life
10000000 (Mechanical)Cycles
Contact Material
Silver Alloy
Minimali darbinė temperatūra
-20°C
Serija
PSR-SCF- 24UC/URM/4X1/2X2
Kilmės šalis
Germany
Produkto aprašymas
PSR Forcibly Guided Coupling Relays
The PSR universal safety relays from Phoenix Contact are equipped with forcibly guided contacts as per EN 50205 for safe isolation.
The configurable coupling relays are a reliable choice to ensure the maximum safety to people and machinery. With forced guidance the N/O (Normally Open) and N/C (Normally Closed) contacts of an elementary relay are mechanically joined together. This stops the N/O and N/C contacts closing at the same time. When used with a suitable circuit, failure to open is detected.
The relays are often used for power amplification, electrical isolation and for increasing the number of contacts
Standards
DIN EN 50178, VDE 0160.
Sandėlio informacija laikinai nepasiekiama.
Patikrinkite dar kartą.
€ 86,92
už 1 vnt. (be PVM)
€ 105,17
už 1 vnt. (su PVM)
1
€ 86,92
už 1 vnt. (be PVM)
€ 105,17
už 1 vnt. (su PVM)
1
Techniniai dokumentai
Specifikacijos
Markė
Phoenix ContactCoil Voltage
24V dc
Tvirtinimo tipas
DIN Rail
Contact Configuration
4NO/2NC
Switching Current
6A
Coil Power
1.25W
Maximum Switching Current AC
6 A
Maximum Switching Current (AC)
6 A
Maximum Switching Current DC
6 A
Maximum Switching Current (DC)
6 A
Maximum Switching Voltage DC
250V
Maximum Switching Voltage (DC)
250V
Maximum Switching Voltage AC
250V
Maximum Switching Voltage (AC)
250V
Terminal Type
Screw
Approvals
CE, cULus
Standards Met
cUL Listed, CULus, UL Listed
Maksimali darbinė temperatūra
+55°C
Isolation Coil To Contact
4kV
Gylis
55mm
Aukštis
111mm
Ilgis
40mm
Life
10000000 (Mechanical)Cycles
Contact Material
Silver Alloy
Minimali darbinė temperatūra
-20°C
Serija
PSR-SCF- 24UC/URM/4X1/2X2
Kilmės šalis
Germany
Produkto aprašymas
PSR Forcibly Guided Coupling Relays
The PSR universal safety relays from Phoenix Contact are equipped with forcibly guided contacts as per EN 50205 for safe isolation.
The configurable coupling relays are a reliable choice to ensure the maximum safety to people and machinery. With forced guidance the N/O (Normally Open) and N/C (Normally Closed) contacts of an elementary relay are mechanically joined together. This stops the N/O and N/C contacts closing at the same time. When used with a suitable circuit, failure to open is detected.
The relays are often used for power amplification, electrical isolation and for increasing the number of contacts
Standards
DIN EN 50178, VDE 0160.