Techniniai dokumentai
Specifikacijos
Markė
Phoenix ContactVoltage Protection Rating
250V ac
Maximum Surge Current
100kA
Serija
FLT-CP-1S-350
Mounting Style
DIN Rail
Impulse Discharge Current
25kA
Ilgis
95.8mm
Plotis
71.6mm
Gylis
70mm
Matmenys
95.8 x 71.6 x 70mm
Minimali darbinė temperatūra
-40°C
Maksimali darbinė temperatūra
+80°C
Operating Temperature Range
-40 → +80 °C
Kilmės šalis
Germany
Produkto aprašymas
Single & 3-phase Mains FLT & VAL Series
Pluggable modules on a fixed base element, for easy installation and fast replacement.
Standards
IEC 61643, VDE V 0185-3
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Sandėlio informacija laikinai nepasiekiama.
Patikrinkite dar kartą.
€ 679,25
už 1 vnt. (be PVM)
€ 821,89
už 1 vnt. (su PVM)
1
€ 679,25
už 1 vnt. (be PVM)
€ 821,89
už 1 vnt. (su PVM)
1
Pirkti dideliais kiekiais
kiekis | Vieneto kaina |
---|---|
1 - 9 | € 679,25 |
10 - 19 | € 612,75 |
20 - 24 | € 551,00 |
25 - 49 | € 494,00 |
50+ | € 445,55 |
Techniniai dokumentai
Specifikacijos
Markė
Phoenix ContactVoltage Protection Rating
250V ac
Maximum Surge Current
100kA
Serija
FLT-CP-1S-350
Mounting Style
DIN Rail
Impulse Discharge Current
25kA
Ilgis
95.8mm
Plotis
71.6mm
Gylis
70mm
Matmenys
95.8 x 71.6 x 70mm
Minimali darbinė temperatūra
-40°C
Maksimali darbinė temperatūra
+80°C
Operating Temperature Range
-40 → +80 °C
Kilmės šalis
Germany
Produkto aprašymas
Single & 3-phase Mains FLT & VAL Series
Pluggable modules on a fixed base element, for easy installation and fast replacement.
Standards
IEC 61643, VDE V 0185-3
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.