Techniniai dokumentai
Specifikacijos
Markė
DehnSuppressor Type
Surge Arrester Protection Module
Maximum Voltage Rating
275 V ac, 350 V dc
Tvirtinimo tipas
Plug In
Maximum Surge Current
40kA
Serija
DG
Ilgis
45mm
Gylis
18mm
Aukštis
51mm
Matmenys
45 x 18 x 51mm
Kilmės šalis
Germany
Produkto aprašymas
DEHNguard and DEHNrail Replacement Plugin Modules
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
Sandėlio informacija laikinai nepasiekiama.
Patikrinkite dar kartą.
€ 113,05
€ 113,05 už 1 vnt. (be PVM)
€ 136,79
€ 136,79 už 1 vnt. (su PVM)
1
![sticker-462](https://cms.rsdelivers.com/repository-v1/nuolaida-7.gif)
€ 113,05
€ 113,05 už 1 vnt. (be PVM)
€ 136,79
€ 136,79 už 1 vnt. (su PVM)
1
![sticker-462](https://cms.rsdelivers.com/repository-v1/nuolaida-7.gif)
Pirkti dideliais kiekiais
kiekis | Vieneto kaina |
---|---|
1 - 4 | € 113,05 |
5 - 9 | € 108,30 |
10 - 24 | € 101,65 |
25+ | € 92,62 |
Techniniai dokumentai
Specifikacijos
Markė
DehnSuppressor Type
Surge Arrester Protection Module
Maximum Voltage Rating
275 V ac, 350 V dc
Tvirtinimo tipas
Plug In
Maximum Surge Current
40kA
Serija
DG
Ilgis
45mm
Gylis
18mm
Aukštis
51mm
Matmenys
45 x 18 x 51mm
Kilmės šalis
Germany
Produkto aprašymas
DEHNguard and DEHNrail Replacement Plugin Modules
Surge Protection Devices, SPDs (DIN-rail)
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.